Option J - Image CapturePopular

Features:

The Kingfisher Image Capture device is used to capture and send images over an existing Kingfisher RTU/SCADA communications network.

 

Image capture can be initiated via an RTU ladder logic command or via the Image Manager application software. A number of images may be stored within the RTU memory in JPEG format. These can be downloaded to a PC using the Image Manager application software where they can be viewed.

 

Images captured can be sent via your existing Kingfisher RTU/SCADA network using serial, radio, GSM, PSTN, etc.

 

NOTE: Camera not included (camera requires PAL/NTSC 75 ohm composite analog output).

  • Image capture option board
  • Capture images from up to 2 cameras
  • Fits CP-10, CP-11, MC-10, MC-11
  • COMMS-OPTION-J (Image Capture -  for CP-11/CP-21/MC-11, option port 2/3)
  •    

    Product specifications:

    General
       
    Configuration Software Kingfisher Toolbox or Image Manager Software
    Camera Trigger RTU Ladder Logic or Image Manager Software
    Picture Uploading/Viewing Image Manager Software
    Maximum Resolution PAL 352 x 288 pixels (100K pixels)
    Colour Coding 16 bits/pixel - luminance and chrominance
    Number of Camera inputs 2
    Camera Input Socket Type SMB Male (on option board)
    Camera Input 1 or 2

    75-Ohm composite camera (analog)*
    PAL or NTSC

    Signal Input Levels

    0.5Vpp to 1.9Vpp (peak to peak)
    1Vpp recommended

    Camera Cable Recommendations (2.5m RG179 camera cable is included in kit, female BNC at Camera end. Camera requires Male BNC to connect.)
    Up to 100m: RG-59
    Up to 250m: RG-6
    Up to 400m: RG-11
    Form Factor Standard Series II daughter board
       
    Electrical
    Camera Input Impedence 75-Ohm nominal
    Camera Input Bandwidth 7Mhz nominal
    Normal Camera Input 0.5V Minimum, 1.0V nominal, 1.9V Peak
    Absolute Camera Input -0.7V minimum, 6.0V Peak
    Supply Current (Internal 5V) 500mA nominal
       
    Environmental Parameters
     
    Operating Temperature 0°C to 70°C / 32°F to 158°F
    Storage Temperature -40°C to 125°C / -40°F to 257°F
    Relative Humidity 5 to 95% non-condensing
       
    Image Size
       
    Large PAL 352 x 288 / NTSC 320 x 240 pixels
    Small PAL 176 x 144 / NTSC 160 x 120 pixels